Ventara Air Humidity single room heat recovery ventilator

Ventara Air Humidity is a single room heat recovery ventilator that ventilates one room through one outside-wall opening for a 158 mm duct. Every 75 seconds its fan reverses. The ceramic core stores heat from the stale air going out and hands it to the fresh air coming in.

Ventara Air Humidity unit with its square white front panel fitted through a brick wall
maximum heat recovery
97%
lowest speed at 1.5 m
18.9dB(A)
power at low speed
4.7W

Who Air Humidity is for

Air Humidity is for one room with an outside wall where ducts cannot run.

Need app control and schedules? See Air Humidity WiFi with app control.

Cutaway of a wall showing the Ventara Air Humidity duct running from the inside panel to the outside hood
  • Ceramic regenerator

    A ceramic core treated for hygiene recovers up to 97% of thermal energy with low airflow resistance. A heat storage ball regenerator is available as an option.

  • Humidity sensor

    A humidity sensor switches the unit from regeneration to exhaust in response to high humidity.

  • Auto shutter

    The shutter closes when the unit stops. It keeps out dust, insects and cold draughts.

  • Quiet DC fan

    A reversible fan runs at three speeds. Sound pressure is 18.9 dB(A) at the lowest speed when measured 1.5 m from the unit.

  • Filters

    Washable pre-filters come as standard. An F7 filter is optional.

  • Controls

    Button and remote control as standard. Air Humidity WiFi adds app control.

When Air Humidity changes what it is doing

Air Humidity switches from regeneration to exhaust in response to high humidity. The light on the front shows which mode it is in.

  1. WhenYou press boost on the remote
    Air Humidity doesRuns at its highest speed
    Until30 minutes pass with no other button pressed
  2. WhenThe filters have run for 960 hours
    Air Humidity doesFlashes red as a cleaning reminder
    UntilYou clean the filter and hold Filter Reset on the remote for 5 seconds

Humidity control matters most in rooms prone to condensation. See what the guidance says about damp, mould and ventilation.

Reading the light on the front panel

  • BlueRegeneration: the 75 second heat recovery cycle
  • GreenSupply only: fresh air in
  • RedExhaust only: stale air out
  • Blue flashingExhausting because humidity is high
  • Red flashingTime to clean the filter

Inside Air Humidity

A simplified view of the main components from the Ventara catalogue. Match the numbers to the parts below.

Exploded view of Ventara Air From the room outwards: front panel, pre-filter, F7 filter, ceramic core, reversible fan, wall sleeve and outer hood. 7 Outer hood 5 Reversible EC fan 4 Ceramic core 3 F7 filter (optional) 2 Pre-filter 6 Wall sleeve 1 Front panel OutsideRoom side
  1. 1
    Front panelSquare panel. An auto shutter behind it closes when the unit stops.
  2. 2
    Pre-filterWashable pre-filters as standard.
  3. 3
    F7 filter (optional)An optional extra on the Air models.
  4. 4
    Ceramic coreStores and returns heat. Maximum heat recovery efficiency of 97%.
  5. 5
    Reversible EC fanThree speeds. Reverses every 75 seconds in heat recovery mode.
  6. 6
    Wall sleeveThe 158 mm diameter duct through the outside wall.
  7. 7
    Outer hoodCovers the duct outside. Metal and plastic hoods are listed.

Air shown. Air Humidity and Air Humidity WiFi share the same parts. Air+ has a curved magnetic panel and F7 as standard.Not to scale.

How quiet is Air Humidity?

18.9dB(A)

For comparison a whisper is about 30 dB.

Air Humidity catalogue sound pressure levels. The 18.9 dB(A) low-speed figure was tested at 1.5 m. The technical table does not give a distance for medium or high speed. Everyday sounds are approximate references and not like-for-like tests. Everyday sound levels: whisper from ASHA (opens in a new tab), library and conversation from RNID (opens in a new tab).

The 75 second cycle

Air Humidity has one reversible fan and a ceramic core. Watch it store heat on the way out and hand it back on the way in. Drag the slider to stop at any second. The full explanation is in how single room heat recovery works.

Breathing out. Warm stale air leaves the room and heats the ceramic core on its way past.

Shown at ten times real speed. Example winter day with 2°C outside and 20°C inside.

What does Air Humidity cost to run?

Pick a setting and the hours it runs. The cost uses the catalogue power figure and the current Ofgem price cap rate of 26.32p per kWh.

Speed

£3.16a year

£0.26 a month · 12 kWh a year

Uses the catalogue power at each fan speed for Air Humidity. Estimate at the Ofgem price cap average electricity unit rate for 1 October to 31 December 2026 (standard variable tariff, Direct Debit, Great Britain average). The government has removed VAT from electricity bills from 1 October 2026 to 31 March 2027. Standing charge not included. Your rate depends on your region and tariff. Source: Ofgem, 26 August 2026 (opens in a new tab).

Air Humidity specifications

SpecificationLowMediumHigh
Airflow (m³/h)305060
Airflow (CFM)17.629.435.3
Power (W)4.75.66.5
Sound pressure (dB(A))18.925.228.7
Regeneration efficiencyUp to 97%
Voltage100 to 240 V AC, 50/60 Hz
Max fan speed2,200 rpm
Duct diameter158 mm
Unit size230 x 243 x 499.7 mm
Wall depth (duct length)280 to 470 mm
Net weight3.9 kg

Scroll the table sideways on a small screen to see every speed.

Airflow figures are for supply or exhaust mode with the F7 filter fitted. Airflow without F7 is about 34, 56 and 70 m³/h. The 18.9 dB(A) figure is measured at low speed from 1.5 m away.

See every model side by side in the single room comparison.

Installing Air Humidity

  • Core-drill one hole through the outside wall for the 158 mm duct.
  • Check the wall depth and installation requirements before choosing a unit. A thin-wall kit and a 390 mm extension pipe (total pipe length up to 600 mm) are listed as accessories.
  • The accessory list includes plastic and metal outer hoods in white or black. A heated metal hood is also listed.

Air Humidity is supplied in the UK and Ireland by Fresh Air Supplies. See Ventara Air Humidity at Fresh Air Supplies (opens in a new tab).

  • Cutaway of a wall showing the Ventara Air Humidity duct running from the inside panel to the outside hood
  • Ventara Air Humidity front panel and wall sleeve with outer hood laid out side by side
  • Ventara Air unit shown with a remote and the Wi-Fi app
  • Ventara Air Humidity shown in a wall section beside a window

Air Humidity questions

How does Air Humidity recover heat with only one fan?

Ventara Air Humidity reverses its fan every 75 seconds. Warm stale air heats the ceramic core on the way out. Cold fresh air picks that heat back up on the way in. The core recovers up to 97% of the heat with no second fan and no ductwork.

What is the difference between Air Humidity and Air Humidity WiFi?

Ventara Air Humidity WiFi adds a Wi-Fi module, an app for iOS and Android and wireless pairing. Both have a humidity sensor and a ceramic core. Choose Air Humidity WiFi for schedules, groups, voice control and paired units.

Can the pre-filters be washed?

Ventara Air Humidity has washable pre-filters. An F7 filter is available as an option.

Single room or ducted MVHR: which do I need?

A single room unit uses a 158 mm duct through an outside wall. Breathe supplies and extracts at the same time through four duct connections in a ceiling void. Ask us to check the sizing and installation requirements for your building.

How much electricity does a single room unit use?

Electricity use depends on fan speed and running time. Use the running-cost tool on this page to explore the catalogue settings.

What wall thickness do single room units need?

Air and Air+ use a 158 mm duct through an outside wall. Ask us to check the wall depth and any accessories needed before choosing a unit.

How quiet is this unit?

Air Humidity and Air Humidity WiFi measure 18.9 dB(A) at the lowest speed from 1.5 m away. The catalogue gives 25.2 dB(A) at medium and 28.7 dB(A) at high speed, without a measuring distance for those settings.

What is the difference between Air and Air+?

Air has a humidity sensor and a square front. Air+ has a temperature sensor for free cooling, an F7 filter as standard and a curved magnetic front. Both ranges have a humidity version; Air+ also has a CO₂ version.